Structural Steel Rack and foundations for Pipe Support and Mud Wash Pump for Crude Unit A Refinery at Beaumont, Texas
Scope: Detailed structural design of miscellaneous pipe support structures, including foundations and mud-wash pump foundations.
Analysis: Developed structural analysis models for pipe support posts to evaluate critical load combinations, integrating piping stress analysis reactions with gravity, wind, and seismic loads.
Design Optimization: Sized structural steel members and engineered connections to ensure full structural integrity and code compliance.
Deliverables: Provided comprehensive calculation reports authenticated with a Professional Engineering (PE) stamp.
Structural Steel Support and Foundation for Permian Basin Oilfield Wastewater Pump station at Eddy County, New Mexico
Scope: Detailed structural design of the pump foundations, associated power skid, and pipeline support structures.
Analysis: Developed structural analysis models for pipe support structures considering piping stress analysis reactions. Additionally, Finite Element Analysis (FEA) model to evaluate pump mat foundation.
Design Optimization: Developed an optimized structural system for pipe support racks and engineered member sizes and detailed connections to ensure full structural integrity and code compliance. Optimized mat foundation thickness and required steel reinforcement.
Deliverables: Provided comprehensive calculation reports complete with a Professional Engineering (PE) stamp for official authentication.
Selective Catalytic Reduction (SCR) System For Gas Turbine at Power Plant in Alberta
Scope: Detailed structural design of the SCR reactor, Exhaust Stack, Tempering Air Duct Support Rack, and Waste Heat Recovery Unit (WHRU), including the calculation of foundation reactions.
Analysis: Developed advanced 3D FEA models for each structure to evaluate critical load combinations (gravity, internal pressure, and environmental loads).
Design Optimization: Engineered structural steel member sizes, connections and duct-casing stiffening to ensure structural integerty and code compliance.
Deliverables: Provided comprehensive calculation reports complete with a Professional Engineering (PE) stamp for official authentication.
Selective Catalytic Reduction (SCR) System For Gas Turbine at Power plant in North Dekota
Scope: Detailed structural design of the SCR reactor and Exhaust Stack including the calculation of foundation reactions.
Analysis: Developed advanced 3D FEA models for both the SCR reactor and the exhaust stack for detailed structural analysis.
Design Optimization: Engineered structural steel member sizes, connections and duct-casing stiffening to ensure structural integerty and code compliance.
Deliverables: Provided comprehensive calculation reports complete with a Professional Engineering (PE) stamp for official authentication.
Gas Turbine Bypass Stack at Power PLant in Puerto Rico
Scope: Review and approval of detailed structural calculations for the bypass stack system.
Analysis: Developed precise 3D FEA models to determine the stack's natural frequencies, providing critical data to evaluate dynamic wind loads, resonance, and vortex-induced vibrations.
Deliverables: Comprehensive calculation report review and authentication with a Professional Engineering (PE) stamp.